Java程序辅导

C C++ Java Python Processing编程在线培训 程序编写 软件开发 视频讲解

客服在线QQ:2653320439 微信:ittutor Email:itutor@qq.com
wx: cjtutor
QQ: 2653320439
Prosthetic socket design : from a multi-indenter device for in vivo biomechanical tissue measurement to a quasi-passive transtibial socket interface MIT Libraries homeDSpace@MIT MIT View Item  DSpace@MIT Home MIT Libraries MIT Theses Doctoral Theses View Item DSpace@MIT Home MIT Libraries MIT Theses Doctoral Theses View Item JavaScript is disabled for your browser. Some features of this site may not work without it. Toggle navigation Prosthetic socket design : from a multi-indenter device for in vivo biomechanical tissue measurement to a quasi-passive transtibial socket interface Author(s) Petron, Arthur J DownloadFull printable version (31.61Mb) Alternative title From a multi-indenter device for in vivo biomechanical tissue measurement to a quasi-passive transtibial socket interface Other Contributors Program in Media Arts and Sciences (Massachusetts Institute of Technology) Advisor Hugh M. Herr. Terms of use M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 Metadata Show full item record Abstract The prosthetic socket, the mechanical interface between an amputated residuum and an external prosthesis, is of critical importance to the performance of a prosthetic limb system. Conventional prosthetic socket technology is derived using a non-quantitative, artisan methodology. Consequently, a comfortable socket interface cannot be made reproducibly, and persons with limb amputation too often experience discomfort. As a resolution to this difficulty, the field of digital prosthetic socket design seeks to advance a quantitative CAD/CAM methodology for socket production to produce reproducible and comfortable interfaces. Prosthetic researchers have proposed a digital socket production work flow comprising the steps of 1) assessment of residuum tissue biomechanics; 2) modeling optimization of the residuum-socket interface, and 3) fabrication of a variable-impedance socket system based upon these optimizations. In this thesis, two novel technologies are designed, built and evaluated at either end of this work flow, namely a multi-indenter device for in vivo biomechanical tissue measurement and a quasi-passive variable-impedance transtibial socket interface. An active indenter platform called the FitSocket is presented. To assess residual-limb tissue biomechanics, the FitSocket comprised 14 position and force controllable actuators that circumferentially surround a biological residuum to form an actuator ring. Each actuator is individually controllable in position (97.1?m accuracy) and force (330mN accuracy) at a PC controller feedback rate of 500Hz, allowing for a range of measurement across a residuum. At five distinct anatomical locations across the residual limb, force versus deflection data are presented, demonstrating the accuracy and versatility of the FitSocket for residual limb tissue characterization. A passive, single indenter version of the FitSocket, called the FitPen, is also presented. The FitPen is designed to be ultra-portable in order to take biomechanical measurements in the field outside the laboratory setting. A quasi-passive socket (QPS) is presented having spatially and temporally varying socket wall impedances. The QPS is an autonomous computerized transtibial prosthetic interface that can stiffen or become compliant using computer-controlled electrolaminate actuators. The QPS measures forces applied by the limb on the socket, 3-axis acceleration of the socket, and the position of the electrolaminates. On a test participant with transtibial amputation, the socket was evaluated through sit-to-stand tests to determine the viability of computer-controlled electrolaminate engagement, and through a walking study to evaluate the ability of the electrolaminates to maintain their clutched state during ambulation at a self-selected walking speed. The average deflections of forced tibia movement in the sit-to-stand tests were 7 ± 2 mm while sitting with the electrolaminates in an unclutched state, and 2.1 ± 0.6 mm while standing with the electrolaminates in a clutched state. Further, the walking study showed a maximum unclutched deflection (3.7 ± 0.9 mm)16 times larger than that of the maximum deflection while clutched. This work was supported by the United States Department of Veteran Affairs through the VA Innovation Initiative (VAi2) program. Description Thesis: Ph. D., Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2016.  Cataloged from PDF version of thesis.  Includes bibliographical references (pages 183-197).   Date issued2016 URI http://hdl.handle.net/1721.1/106068 Department Program in Media Arts and Sciences (Massachusetts Institute of Technology) Publisher Massachusetts Institute of Technology Keywords Program in Media Arts and Sciences () Collections Doctoral Theses Show Statistical Information Search DSpace This Collection Browse All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects My Account Login Statistics OA StatisticsStatistics by CountryStatistics by Department MIT Libraries home Find us on Twitter Facebook Instagram YouTube RSS MIT Libraries navigation SearchHours & locationsBorrow & requestResearch supportAbout us PrivacyPermissionsAccessibility MIT Massachusetts Institute of Technology Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.