Java程序辅导

C C++ Java Python Processing编程在线培训 程序编写 软件开发 视频讲解

客服在线QQ:2653320439 微信:ittutor Email:itutor@qq.com
wx: cjtutor
QQ: 2653320439
Restricted Electrical Licence (REL) | TAFE Queensland Current students News Events Contact us Courses Close Courses Study areas Study areas Health and science Business and IT Creative industries Education and community Environment and animal services Infrastructure and transport Service industries Trades Course types Course types Short courses and micro-credentials Certificate courses Diplomas and advanced diplomas Degrees English Language and Literacy Services AMEP Ways to study Ways to study TAFE at School Online learning Recognition of Prior Learning (RPL) Short courses and micro-credentials Study on campus Traineeships Apprenticeships Apply and enrol Apply and enrol How to apply What it costs Scholarships Subsidised training Entry requirements University pathways University pathways Our campus locations Our campus locations Search courses Search courses What it costs What it costs Trade training Close Trade training Become an apprentice or trainee Become an apprentice or trainee Trade courses Trade courses Trade employers Trade employers International Close International How to apply How to apply International student support International student support Study tours Study tours Life in Australia Life in Australia Frequently asked questions Frequently asked questions Agents and partners Agents and partners International courses International courses Employers Close Employers Our industry sectors Our industry sectors Funding and incentives Funding and incentives Case studies Case studies Dingo Diggers Partnerships Partnerships Trade employers Trade employers Small Business Solutions Small Business Solutions About us Close About us Who we are Who we are Our campus locations Our campus locations Our services Our services Life at TAFE Life at TAFE Working for TAFE Queensland Working for TAFE Queensland Our facilities Our facilities Libraries Animal care Beauty and hairdressing Clinical labs Creative spaces Gyms and sports facilities Hospitality hubs Maritime facilities Trade facilities Policy and governance Policy and governance Contact us Contact us Current students News Events Contact us Personalise My View Close I am searching for Courses Everything else Commonly used Nursing Child care Business and management Automotive Dental Electrotechnology Allied health Horticulture Beauty Community services Personalise my view Personalise my view Close 😊 Personalise my view I am a school leaver a career enhancer a TAFE student an international student a parent an employer a guidance counsellor a high school student interested in studying Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades interested in studying Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades currently studying Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades interested in studying Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades interested in Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades interested in Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades interested in Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades interested in studying Any Business and IT Creative industries Education and community Environment and animal services Health and science Infrastructure and transport Service industries Trades at Any Greater Brisbane Gold Coast Sunshine Coast Darling Downs & South West Wide Bay Burnett North Queensland Far North Queensland Campus Any Campus Acacia Ridge Alexandra Hills Mt Gravatt Bracken Ridge Caboolture Eagle Farm Grovely Inala Ipswich Loganlea Redcliffe South Bank Springfield Campus Ashmore Coomera Coolangatta Coomera Marine Robina Southport Campus Mooloolaba Nambour Sunshine Coast Health Institute Maroochydore Campus Roma Warwick Charleville Chinchilla Dalby Toowoomba Lockyer Valley - Gatton Campus Bundaberg Gympie Hervey Bay Kingaroy Maryborough Nurunderi Campus Bowen Burdekin Charters Towers Cloncurry Palm Island Ingham Mount Isa Normanton Townsville (Pimlico) The Whitsundays Townsville (Trade Training Centre Bohle) Campus Atherton Cairns Innisfail Thursday Island Northern Peninsula Area Great Barrier International Marine College Personalise view Reset We use cookies and third-party to provide a better online experience, including to serve targeted ads. By using our website, you accept our use of cookies and privacy agreement.  Learn more Close SSUEE0010 Restricted Electrical Licence (REL) Skill Set Get skills to apply for a restricted Electrical licence Ask a question Apply Now Download Course Brochure TIME 3 days / Full Time NEXT START DATE 09 May 2022 STUDY LOCATIONS Greater Brisbane Gold Coast Far North Queensland WAYS TO STUDY On Campus WHAT YOU'LL PAY Full Fee $6,980 Jump to section Course overview Ways to study Payment options Important information Ask a question Apply Now Course overview Qualified tradespeople may apply for a restricted Electrical Licence, which requires skill sets including: composite equipment, instrumentation/process control, plumbing and gas, electric motors, electronics and refrigeration, and air-conditioning. The number of competencies required depends on your existing electrical work training permit. Restricted Electrical Work Licences do not authorise the holder to carry out installation work. You will receive a Statement of Attainment, but not the full Certificate III in Appliance Service qualification. Course outcome: Statement of Attainment Construction Skills Queensland (CSQ) Funding TAFE Queensland is a proud recipient of Construction Skills Queensland (CSQ) funding and is a registered provider in the CSQ Short Course and Apprentice Advance Plus programs - several units in this course are subsidised under one of these programs. It is important to note only eligible participants may receive funding for eligible courses. Learn more about eligibility criteria. What you will study. Units will vary depending on individual student requirements and location of study. Core units UNIT CODE UNIT NAME UNIT CODE UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace UNIT CODE : UEENEEE101A Unit description : This unit specifies the mandatory requirements of occupational health and safety and how they apply to the various electrotechnology work functions. It encompasses responsibilities for health and safety, risk management processes at all operative levels and adherence to safety practices as part of the normal way of doing work. UNIT NAME Apply Occupational Health and Safety regulations, codes and practices in the workplace Elective Units UNIT CODE UNIT NAME Greater Brisbane Greater Brisbane UNIT CODE UEENEEP010A Disconnect/reconnect appliances connected to low voltage installation wiring UNIT CODE : UEENEEP010A Unit description : This unit covers disconnecting and reconnecting appliances connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work). Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect/reconnect appliances connected to low voltage installation wiring UNIT CODE UEENEEP012A Disconnect/reconnect composite appliances connected to low voltage installation wiring UNIT CODE : UEENEEP012A Unit description : This unit covers disconnecting and reconnecting composite appliances connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work). UNIT NAME Disconnect/reconnect composite appliances connected to low voltage installation wiring UNIT CODE UEENEEP013A Disconnect/reconnect control devices connected to low voltage installation wiring UNIT CODE : UEENEEP013A Unit description : This unit covers disconnecting and reconnecting control devices connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of, or alteration to, any part of the fixed electrical wiring system (defined as electrical installing work). Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect/reconnect control devices connected to low voltage installation wiring UNIT CODE UEENEEP014A Disconnect/reconnect water heaters connected to low voltage installation wiring UNIT CODE : UEENEEP014A Unit description : This unit covers disconnecting and reconnecting water heaters connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc.); or installation of, or alteration to, any part of the fixed electrical wiring system (defined as electrical installing work). Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect/reconnect water heaters connected to low voltage installation wiring UNIT CODE UEENEEP015A Disconnect - reconnect motors connected to low voltage installation wiring UNIT CODE : UEENEEP015A Unit description : This unit covers disconnecting and reconnecting motors connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect - reconnect motors connected to low voltage installation wiring UNIT CODE UEENEEP016A Locate and rectify faults in low voltage appliances using set procedures UNIT CODE : UEENEEP016A Unit description : This unit covers locating and rectifying fault(s) in appliances intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP010A UNIT NAME Locate and rectify faults in low voltage appliances using set procedures UNIT CODE UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures UNIT CODE : UEENEEP017A Unit description : This unit covers locating and rectifying fault(s) in composite appliances intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEP012A UNIT NAME Locate and rectify faults in low voltage composite appliances using set procedures UNIT CODE UEENEEP018A Locate and rectify faults in low voltage control devices using set procedures UNIT CODE : UEENEEP018A Unit description : This unit covers locating and rectifying fault(s) in control devices intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP013A UNIT NAME Locate and rectify faults in low voltage control devices using set procedures UNIT CODE UEENEEP019A Locate and rectify faults in low voltage water heaters using set procedures UNIT CODE : UEENEEP019A Unit description : This unit covers locating and rectifying fault(s) in water heaters intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP014A UNIT NAME Locate and rectify faults in low voltage water heaters using set procedures UNIT CODE UEENEEP020A Locate and rectify faults in low voltage motors using set procedures UNIT CODE : UEENEEP020A Unit description : This unit covers locating and rectifying fault(s) in motors intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP015A UNIT NAME Locate and rectify faults in low voltage motors using set procedures UNIT CODE UEENEEP021A Disconnect - reconnect explosion-protected appliances and control devices connected to low voltage installation wiring UNIT CODE : UEENEEP021A Unit description : This unit covers disconnecting and reconnecting flame proof, increased safety and intrinsic safety electrical equipment to supply up to 1,000V a.c. or 1,500V d.c. under restrictions of designated electrical equipment and conditions specified. It encompasses working safely in hazardous area, identifying supply arrangements, following isolation procedures, handling explosion-protection equipment, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Other alternatives of prerequisite units may apply. Please see alternatives here: https://training.gov.au/Training/Details/UEENEEP21A Pre-requisite unit : UEENEEE101A , UEENEEP012A UNIT NAME Disconnect - reconnect explosion-protected appliances and control devices connected to low voltage installation wiring UNIT CODE UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230V supply UNIT CODE : UEENEEP024A Unit description : This unit covers attaching flexible cords and plugs to electrical equipment for connection to supplies up to 230V a.c. This may be incidental to or a primary and regular function of work related to a principle function in the workplace. It encompasses working safely, identifying plug configurations, selecting and using testing and measuring devices, terminating and connecting cords/plugs and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A UNIT NAME Attach cords and plugs to electrical equipment for connection to a single phase 230V supply UNIT CODE UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000V a.c. or 1500V d.c. supply UNIT CODE : UEENEEP025A Unit description : This unit covers attaching flexible cords, cables and plugs to electrical equipment connected to a supply up to 1,000V a.c. or 1,500V d.c. This may be incidental to or a primary and regular function of work related to a principle function in the workplace. It encompasses working safely, identifying plug configurations, selecting and using testing and measuring devices, terminating and connecting flexible cords/plugs and conductors, safety testing and reporting. Pre-requisite unit : UEENEEP024A UNIT NAME Attach cords, cables and plugs to electrical equipment for connection to 1000V a.c. or 1500V d.c. supply UNIT CODE UEENEEP026A Conduct in-service safety testing of electrical cord connected equipment and cord assemblies UNIT CODE : UEENEEP026A Unit description : This unit covers safety testing of electrical cord connected equipment and cord assemblies. It encompasses working safely, using portable apparatus tester, identifying faults, applying tagging, arranging for repair of faulty equipment and complete testing documentation. Pre-requisite unit : UEENEEE101A UNIT NAME Conduct in-service safety testing of electrical cord connected equipment and cord assemblies Gold Coast Gold Coast UNIT CODE UEENEEP012A Disconnect/reconnect composite appliances connected to low voltage installation wiring UNIT CODE : UEENEEP012A Unit description : This unit covers disconnecting and reconnecting composite appliances connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work). UNIT NAME Disconnect/reconnect composite appliances connected to low voltage installation wiring UNIT CODE UEENEEP010A Disconnect/reconnect appliances connected to low voltage installation wiring UNIT CODE : UEENEEP010A Unit description : This unit covers disconnecting and reconnecting appliances connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work). Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect/reconnect appliances connected to low voltage installation wiring UNIT CODE UEENEEP013A Disconnect/reconnect control devices connected to low voltage installation wiring UNIT CODE : UEENEEP013A Unit description : This unit covers disconnecting and reconnecting control devices connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of, or alteration to, any part of the fixed electrical wiring system (defined as electrical installing work). Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect/reconnect control devices connected to low voltage installation wiring UNIT CODE UEENEEP014A Disconnect/reconnect water heaters connected to low voltage installation wiring UNIT CODE : UEENEEP014A Unit description : This unit covers disconnecting and reconnecting water heaters connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting. The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc.); or installation of, or alteration to, any part of the fixed electrical wiring system (defined as electrical installing work). Pre-requisite unit : UEENEEE101A UNIT NAME Disconnect/reconnect water heaters connected to low voltage installation wiring UNIT CODE UEENEEP016A Locate and rectify faults in low voltage appliances using set procedures UNIT CODE : UEENEEP016A Unit description : This unit covers locating and rectifying fault(s) in appliances intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP010A UNIT NAME Locate and rectify faults in low voltage appliances using set procedures UNIT CODE UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures UNIT CODE : UEENEEP017A Unit description : This unit covers locating and rectifying fault(s) in composite appliances intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEP012A UNIT NAME Locate and rectify faults in low voltage composite appliances using set procedures UNIT CODE UEENEEP018A Locate and rectify faults in low voltage control devices using set procedures UNIT CODE : UEENEEP018A Unit description : This unit covers locating and rectifying fault(s) in control devices intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP013A UNIT NAME Locate and rectify faults in low voltage control devices using set procedures UNIT CODE UEENEEP019A Locate and rectify faults in low voltage water heaters using set procedures UNIT CODE : UEENEEP019A Unit description : This unit covers locating and rectifying fault(s) in water heaters intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A , UEENEEP014A UNIT NAME Locate and rectify faults in low voltage water heaters using set procedures UNIT CODE UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230V supply UNIT CODE : UEENEEP024A Unit description : This unit covers attaching flexible cords and plugs to electrical equipment for connection to supplies up to 230V a.c. This may be incidental to or a primary and regular function of work related to a principle function in the workplace. It encompasses working safely, identifying plug configurations, selecting and using testing and measuring devices, terminating and connecting cords/plugs and conductors, safety testing and reporting. Pre-requisite unit : UEENEEE101A UNIT NAME Attach cords and plugs to electrical equipment for connection to a single phase 230V supply UNIT CODE UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000V a.c. or 1500V d.c. supply UNIT CODE : UEENEEP025A Unit description : This unit covers attaching flexible cords, cables and plugs to electrical equipment connected to a supply up to 1,000V a.c. or 1,500V d.c. This may be incidental to or a primary and regular function of work related to a principle function in the workplace. It encompasses working safely, identifying plug configurations, selecting and using testing and measuring devices, terminating and connecting flexible cords/plugs and conductors, safety testing and reporting. Pre-requisite unit : UEENEEP024A UNIT NAME Attach cords, cables and plugs to electrical equipment for connection to 1000V a.c. or 1500V d.c. supply UNIT CODE UEENEEP026A Conduct in-service safety testing of electrical cord connected equipment and cord assemblies UNIT CODE : UEENEEP026A Unit description : This unit covers safety testing of electrical cord connected equipment and cord assemblies. It encompasses working safely, using portable apparatus tester, identifying faults, applying tagging, arranging for repair of faulty equipment and complete testing documentation. Pre-requisite unit : UEENEEE101A UNIT NAME Conduct in-service safety testing of electrical cord connected equipment and cord assemblies Note: For some courses, not all electives are available at all campuses. Ways to study On Campus Show courses from Greater Brisbane Gold Coast Far North Queensland CAMPUS START DATES DURATION WORKLOAD STUDY MODE WHAT YOU'LL PAY Eagle Farm 13 Jun 2022 3 days Full time. Up to 5 units required at $474 per unit. UEENEEE101A $170. Monday, Tuesday, Wednesday Classroom Full fee: $6,980 Apply Eagle Farm 05 Sep 2022 3 days Full time. Up to 5 units required at $474 per unit. UEENEEE101A $170. Monday, Tuesday, Wednesday Classroom Full fee: $6,980 Apply Eagle Farm 07 Nov 2022 3 days Full time. Up to 5 units required at $474 per unit. UEENEEE101A $170. Monday, Tuesday, Wednesday Classroom Full fee: $6,980 Apply CAMPUS START DATES DURATION WORKLOAD STUDY MODE WHAT YOU'LL PAY Ashmore 09 May 2022 up to 6 months Cost per unit can vary between $150 and $1015 depending on units chosen - Part time 2 nights per week Monday, Wednesday Classroom Full fee: $6,980 Apply CAMPUS START DATES DURATION WORKLOAD STUDY MODE WHAT YOU'LL PAY Cairns Anytime Varies Part time. Up to 5 units required at $500 per unit. Mixed mode Full fee: $6,980 Apply Studying on campus is a great way to enjoy the benefits of face-to-face education in a way that is far removed from a typical school. No matter which campus you choose, you know that you will be learning in an adult environment where you will be respected and nurtured. Attend a campus to learn face-to-face with a teacher in one of our learning spaces; such as a classroom, workshop, laboratory or simulated environments, or interact with teachers using real-time video or web conference tools. Learn more Courses delivered on campus may have a combination of online and classroom based learning. Students are expected to undertake additional personal study to complete the course requirements. Download Brochure Restricted Electrical Licence (REL) Skill Set (SSUEE0010) On Campus Greater Brisbane Gold Coast Far North Queensland Download Brochure Ask a question Restricted Electrical Licence (REL) Skill Set COURSE CODE: SSUEE0010 By location Greater Brisbane Gold Coast Far North Queensland Eagle Farm Ashmore Cairns Proceed Payment Options How can I pay for this course? No matter what your circumstances, TAFE Queensland has a payment option to suit you. If you are unsure of what’s right for you, get in touch. We’re here to help.  Payment plan If you have difficulty paying for the full cost of a course upfront, you may be eligible for a payment plan. Learn more Upfront payment This may be the full fee for the course, or the student contribution amount if you are eligible for a subsidy or concession. Learn more Important Information Read this before applying. Selection criteria Students must have successfully completed UEENEEP012A before participating in UEENEEP017A. Restricted Electrical License tradespersons or technicians must meet one of the following: overseas qualification recognised by Trade Recognition Australia current trade qualification of Certificate III or above five years experience where you are required to perform incidental electrical work. Applicants must have a suitable qualified supervisor within the workplace. Applicants must be able to produce an Electrical Work Training Permit from the Electrical Safety Office For information on demonstrating a requirement for this licence please click Resources Required Materials list: pen notebook Need to know Once students successfully complete their training with us, they must complete the application process with ESO to receive their Restricted Electrical Licence. Please Note: A restricted electrical work licence does not authorise the holder of the licence to carry out installation work. Prerequisites apply to certain units: students must have successfully completed UEENEEP012A before enrolling in UEENEEP017A students must have successfully completed UEENEEP015A before enrolling in UEENEEP020A students must have successfully completed UEENEEP010A before enrolling in UEENEEP016A students must have successfully completed UEENEEP014A (P010A) before enrolling in UEENEEP019A. Replacement skill set This skill set has been superseded, as of 4 October 2020. A transition period applies to enable current students to complete their study. The transition period finishes on 3 October 2022. If required, enrolments will be transitioned into the replacement qualification. Pathways University Pathways. If you want to go on to further study at university, TAFE Queensland has a pathway option to get you there. In many cases, completing one of our diplomas may give you a full year of credit towards a degree with one of our partner universities. Learn more about University Pathways How to Apply Direct application If you're ready to get started, simply hit the Apply Now button on your preferred course information page and get your application underway online.  Related Courses Certificate III in Electrotechnology Electrician Progress your electrical career with this apprenticeship course. Complete this qualification as part of your apprenticeship to become a qualified electrician and apply for your electrical workers licence. Careers Electrician Certificate III in Air-conditioning and Refrigeration Progress your career in refrigeration and air-conditioning with this apprenticeship course. Become a qualified air-conditioning and refrigeration mechanic and apply for your Restricted Electrical Licence and Full Refrigeration Handling Licence. Careers Air Conditioning and Refrigeration Mechanic Diploma of Air-conditioning and Refrigeration Engineering Advance your existing skill set and broaden your employment opportunities with this advanced course in air-conditioning and refrigeration engineering. Careers Air Conditioning and Refrigeration Paraprofessional Supervisor Project Manager Get in touch Call 1300 308 233 Visit us Message us Study Study Areas Courses Qualifications Pathways to university Ways to study AMEP Quick Links International students Why choose TAFE Queensland How to apply About us Locations Greater Brisbane Gold Coast Sunshine Coast Darling Downs and South West Wide Bay Burnett North Queensland Far North Queensland Contact us General enquiries Media enquiries We acknowledge the traditional owners of the lands on which TAFE Queensland stands. Copyright and disclaimer Privacy policy Right to information Audit Staff Launch Pad Provide feedback CRICOS Provider Code: 03020E  |  Registered Training Organisation Code: 0275  |  Higher Education Provider Code: PRV13003 Chat with us, powered by LiveChat